Übersichtsarbeiten - OUP 03/2017

Operative Therapieoptionen degenerativer Erkrankungen der Lendenwirbelsäule

8. Ghiselli G, Wang JC, Bhatia NN, Hsu WK, Dawson EG: Adjacent segment degeneration in the lumbar spine. J Bone Joint Surg Am 2004; 86-A: 1497–1503

9. Nardi P, Cabezas D, Rea G, Pettorini BL: Aperius PercLID stand alone interspinous system for the treatment of degenerative lumbar stenosis: experience on 152 cases. J Spinal Disord Tech 2010; 23: 203–207

10. Zucherman JF, Hsu KY, Hartjen CA et al.: A multicenter, prospective, randomized trial evaluating the X STOP interspinous process decompression system for the treatment of neurogenic intermittent claudication: two-year follow-up results. Spine (Phila Pa 1976) 2005; 30: 1351–1358

11. Cabraja M, Abbushi A, Woiciechowsky C, Kroppenstedt S: The short- and mid-term effect of dynamic interspinous distraction in the treatment of recurrent lumbar facet joint pain. Eur Spine J 2009; 18: 1686–1694

12. Schwarzenbach O, Berlemann U, Stoll TM, Dubois G: Posterior dynamic stabilization systems: DYNESYS. Orthop Clin North Am 2005; 36: 363–372

13. Cakir B, Ulmar B, Koepp H, Huch K, Puhl W, Richter M: [Posterior dynamic stabilization as an alternative for dorso-ventral fusion in spinal stenosis with degenerative instability]. Z Orthop Ihre Grenzgeb 2003; 141: 418–424

14. Stoll TM, Dubois G, Schwarzenbach O: The dynamic neutralization system for the spine: a multi-center study of a novel non-fusion system. Eur Spine J 2002, 11 Suppl 2: S170–178

15. Schnake KJ, Schaeren S, Jeanneret B: Dynamic stabilization in addition to decompression for lumbar spinal stenosis with degenerative spondylolisthesis. Spine (Phila Pa 1976) 2006; 31: 442–449

16. Schmoelz W, Huber JF, Nydegger T, Dipl I, Claes L, Wilke HJ: Dynamic stabilization of the lumbar spine and its effects on adjacent segments: an in vitro experiment. J Spinal Disord Tech 2003; 16: 418–423

17. Schmoelz W, Huber JF, Nydegger T, Claes L, Wilke HJ: Influence of a dynamic stabilisation system on load bearing of a bridged disc: an in vitro study of intradiscal pressure. Eur Spine J 2006; 15: 1276–1285

18. Grob D, Benini A, Junge A, Mannion AF: Clinical experience with the Dynesys semirigid fixation system for the lumbar spine: surgical and patient-oriented outcome in 50 cases after an average of 2 years. Spine (Phila Pa 1976) 2005; 30: 324–331

19. Bothmann M, Kast E, Boldt GJ, Oberle J: Dynesys fixation for lumbar spine degeneration. Neurosurg Rev 2008; 31: 189–196

20. Beastall J, Karadimas E, Siddiqui M et al.: The Dynesys lumbar spinal stabilization system: a preliminary report on positional magnetic resonance imaging findings. Spine (Phila Pa 1976) 2007; 32: 685–690

21. Di Martino A, Vaccaro AR, Lee JY, Denaro V, Lim MR: Nucleus pulposus replacement: basic science and indications for clinical use. Spine (Phila Pa 1976) 2005; 30 (16 Suppl): S16–22

22. Manchikanti L, Singh V: Review of chronic low back pain of facet joint origin. Pain Physician 2002; 5: 83–101

23. Manchikanti L, Singh V, Falco FJ, Cash KA, Pampati V: Evaluation of lumbar facet joint nerve blocks in managing chronic low back pain: a randomized, double-blind, controlled trial with a 2-year follow-up. Int J Med Sci 2010; 7: 124–135

Fussnoten

1 Orthopädische Universitätsklinik Ulm am RKU, Ulm

2 Donau-Ries Klinik Donauwörth, Klinik für Orthopädie, Unfallchirurgie und Wirbelsäulentherapie, Neudegger Alle 6, 86609 Donauwörth

SEITE: 1 | 2 | 3